Epidemic parenteral exposure to volatile sulfur-containing compounds at a hemodialysis center [Article de Revue]

 
[Exposition parentérale épidémique à des composés sulfurés fugaces dans un centre d'hémodialyse]
SELENIC D ; ALVARADO-RAMY F ; ARDUINO M ; HOLT S ; CARDINALI F ; BLOUNT B ; JARRET J ; SMITH F ; ALTMAN N ; STAHL C
Infection control and hospital epidemiology. 2004/03; 25(3) : 0899-823X
Summary: OBJECTIVE: To determine the cause of acute illness on August 30, 2000, among patients at an outpatient dialysis center (center A). DESIGN: We performed a cohort study of all patients receiving dialysis on August 30, 2000; reviewed dialysis procedures; and analyzed dialysis water samples using microbiologic and chemical assays. SETTING: Dialysis center (center A). PATIENTS: A case-patient was defined as a patient who developed chills within 5 hours after starting hemodialysis at center A on August 30, 2000. RESULTS: Sixteen (36%) of 44 patients at center A met the case definition. All case-patients were hospitalized; 2 died. Besides chills, 15 (94%) of the case-patients experienced nausea; 12 (75%), vomiting; and 4 (25%), fever. Illness was more frequent on the second than the first dialysis shift (16 of 20 vs 0 of 24, P < .001); no other risk factors were identified. The center's water treatment system had received inadequate maintenance and disinfection and a sulfurous odor was noted during sampling of the water from the reverse osmosis (RO) unit. The water had elevated bacterial counts. Volatile sulfur-containing compounds (ie, methanethiol, carbon disulfide, dimethyldisulfide, and sulfur dioxide) were detected by gas chromatography and mass spectrometry in 8 of 12 water samples from the RO unit and in 0 of 28 samples from other areas (P < .001). Results of tests for heavy metals and chloramines were within normal limits. CONCLUSIONS: Parenteral exposure to volatile sulfur-containing compounds, produced under anaerobic conditions in the RO unit, could have caused the outbreak. This investigation demonstrates the importance of appropriate disinfection and maintenance of water treatment systems in hemodialysis centers.(RESUME D'AUTEUR)
Publication
2004/03

Pages
0899-823X

Language
Anglais

Number of ref
22

ID notice
319129

Location Call number Status Date due Barcode
CCLIN Est
CClin Est
CHU de Nancy - Hôpitaux de Brabois
Rue du Morvan
54511 Vandoeuvre le Nancy Cedex
Tél : 03.83.15.34.73
cclin.est@chu-nancy.fr
http://www.cclin-est.org/
CCLIN Ouest
CClin Ouest
CHU Hôtel Dieu
CS 26419
35064 Rennes Cedex 2
Tél : 02.99.87.35.31
isabelle.girot@chu-rennes.fr
http://www.cclinouest.com/
CCLIN Paris Nord
CClin Paris-Nord
96 rue Didot
75014 Paris
Tél : 01.40.27.42.00  
karin.lebascle@sap.aphp.fr
http://www.cclinparisnord.org/
CCLIN Sud-Est
CClin Sud-Est
Hospices Civils de Lyon
Hôpital Henry Gabriel
20 route de vourles
69230 Saint-Genis-Laval
Tél : 04.78.86.49.50
cclinse@chu-lyon.fr
http://cclin-sudest.chu-lyon.fr/
CCLIN Sud-Ouest
CClin Sud-Ouest
CHU de Bordeaux
Hôpital Pellegrin - Bâtiment Le Tondu
33076 Bordeaux
Tél : 05.56.79.60.58
cclin.so@chu-bordeaux.fr
http://www.cclin-sudouest.com/

There are no comments for this item.

Log in to your account to post a comment.
Tags from this library:
No tags from this library for this title.
Log in to add tags.
    average rating: 0.0 (0 votes)
Languages: